MOGAS
Table 2-13, page 2-48 = 0.0621 gallons/Km
0.0621 X 100 X 2 = 12 gallons
12 X 1.5 X 1.5 X 1.3 = 35 gallons
e. CASCOM Pamphlet 700-2 Method determines unit requirements for company size units up to
divisional strength. This method is based on 100 percent TOE strength and not modified (MTOE) configurations.
(1) Table 2-15 gives the Usage Profile based on location and/or type of unit.
(2) Table 2-15 also gives the consumption based on hours or KMs for each equipment type based on
the Special Requirement Code for the unit.
(3) Multiply the Usage Profile data to the corresponding consumption data for the various equipment.
Add the equipment category subtotals for the total unit requirement.
(4) Uses the Standard Requirements Code for each unit. Find parent unit first, then specific unit.
EXAMPLE 1: Compute the MOGAS requirement for one engineer battalion (SRC 05145H720) of an armored
division (SRC 17000H020) for all categories of equipment using Korean profile - 073.
SOLUTION 1:
Step 1 -- Consumption Rates
AB
CE
GN
HG
MH
SG
SV
TI
CC
SR
WV
OV
40.04.5
24.049.20.0
81.70.0
0.0
0.0
0.1
0.0
Step 2 -- Usage Profile
AB
CE
GN
HG
MH
SG
SV
TI
CC
SR
WV
OV
10
10 20
15
20
10
10
4.4
5.2
5.0
48.310
TOTALS:
400 + 450 + 480 + 738 + 817 + 4.83 = 2,889.8 = 2890 gallons MOGAS
QM5200
11-8